BETA CAE Systems
                    logo

May 12, 2022

BETA CAE Systems announces the release of the v21.1.7 of its software suite

Regarding the download of ANSA/EPILYSIS/META/CAD data translator v21.1.7 here


ansa meta image


About this release

BETA CAE Systems announces the release of v21.1.7.

This last version of the ANSA/EPILYSIS/META and KOMVOS v21.1.x series, hosts numerous fixes in recently detected issues, a highlighted selection of which is featured below:

Contents

Common issues resolved
Enhancements and known issues resolved in ANSA
Enhancements and known issues resolved in EPILYSIS
Enhancements and known issues resolved in META
CAD data translator
Recommended GPU (OpenCL Support) requirements
Virtual Machine Environment


 

go to top

Common issues resolved

Communication with License Manager

A new option to "Save & Retry" for license has been added in the CONFIRMATION dialogue window that pops up in ANSA and META, when the communication with the license server is interrupted. In this way, the user will be able to first save the file and then retry re-acquire license.

Graphics

ANSA and META could potentially fail to launch on a unique display, while executing batch jobs in parallel via VirtualX.

 

go to top

Enhancements and known issues resolved in ANSA

Known issues resolved in ANSA

Connections & Assembly

The calculation of skipped adhesive elements (Cut-off Adhesives) for spotweld and adhesive line realization would produce erroneous results.

Safety

Unexpected termination of the Seatbelt Tool would occur, when changing the Number of Shells during Seatbelt re-creation.

Scripting

The Node Ids would be erroneously renumbered and duplicated, when using the function base.AddToModelContainer(), because of the numbering rules applied on the Model Browser container of the Nodes.

 

go to top

Enhancements and known issues resolved in EPILYSIS

Known issues resolved in EPILYSIS

SOL200

Unexpected termination would occur in optimization with frequency response, coupled with enforced motion.

In SOL200 runs, the CDAMP1/CDAMP3 elements would not be connected correctly with PDAMP properties. In addition, values from DVPREL entries would not be not passed.

 

go to top

Enhancements and known issues resolved in META

Known issues resolved in META

BETA Packager Installer

The Toolbars Packager can now handle function calls that use the "dotted" notation. The dots will be automatically replaced by double underscores, so that the respective functions are created without any issues.

Nastran

Unexpected termination could occur while reading curves from .h5 files, due to memory leak.

Pam-Crash

Results could not be loaded correctly while reading .erfh5 files.

Managing Curve Data

When reading Contribution analysis results without Total Curve, the corresponding plots were not populated correctly.

LS-DYNA: Curves would not be properly plotted from a binout file, when the same Id was available for different entity types of 'swforc'.

Total Panel contributions would not be not read correctly for NX-Nastran.

Subcases States were missing when reading Nastran .h5 SOL111 results with Stresses.

NVH Calculators & Modal Response

FS Coupling: Too many structural elements would be included in the FSI, when the fluid mesh penetrated the surrounding structure in a way that the free surface rested significantly outside the surrounding panels.

When two FLUID PIDs had common faces, the FSI calculation would occasionally take into account faces which were not part of the outer surface of the fluid.

Fixed inaccurate numerical transient response analysis results, in cases where rigid body modes contributed to the response.

 

go to top

CAD data translator

The supported CAD-data formats handled by the CAD DATA Translators are listed below.

-CATIA V5 (R7 - V5-6R2021(CATIA V5 R31)) [.CATPart],[.CATProduct]
 Tesselated data [.cgr]

-CATIA V6 (2011x - 2013x)) [.3Dxml]
-3DExperience (2014 - 2020x) [.3Dxml]
-NX (CT based, Unigraphics V11.0 - NX1957,NX CR 1980) [.prt]
-NX (UG Open based, NX9, NX10, NX11, NX12, NX1847, NX1872, NX1899, NX1953) [.prt]
-Parasolid (all - 33) [.xmt_txt],[.xmt_bin],[.x_b],[.x_t]
-Pro/ENGINEER (from WF3 to WF5),
 PTC Creo Parametric 2.0 M140, PTC Creo Parametric 3.0 M020,
 PTC Creo Parametric 3.0 M030, PTC Creo Parametric 3.0 M040,
 PTC Creo Parametric 3.0 M090, PTC Creo Parametric 4.0 F000,
 PTC Creo Parametric 5.0 - 8.0
-SolidWorks (2007 - 2021) [.sldprt],[.sldasm]
-JT (v8.0 - v10.7) [.jt]
-Inventor (2010 - 2021) [.ipt],[.iam]
-CoreTechnologie [.ctp],[.cta]
-Rhino(up to v6) [.3dm]
-ACIS(R27) [.sat]

 

go to top

Recommended GPU (OpenCL Support) requirements

The following presents the recommended GPU requirements.:

 GPU :NVIDIA�AAMD
 OpenGL Version:3.3
 GPU memory :1GB
 OpenCL Version:1.2


go to top

Virtual Machine Environment

-Any instance of an application launched through a Virtual Machine or Machine of NIC Teamng will not share the same license and will occupy the prescribed number of credits.

 

Regarding the download of ANSA/EPILYSIS/META/CAD data translator v21.1.7 here


BETA CAE Systems Japan Inc.
2-6-3, Shinyokohama, Kohokuku, Yokohama, Kanagawa, 222-0033, Japan
T: 045-478-3840 | Email: support@beta-cae.jp | http://www.beta-cae.jp/english.html

In case user account and password are unknown,please contact our sales team Email: sales@beta-cae.jp
If you have any technical questions about BETA CAE Systems softwares,please contact our technical team
Email: support@beta-cae.jp


Release Announcement BETA CAE Systems suite v21.1.7