BETA CAE Systems
                    logo

BETA CAE Systems
                    logo

April 15, 2025

BETA CAE Systems announces the release of the v24.1.5 of its software suite

Regarding the download of ANSA/EPILYSIS/META/CAD data translator v24.1.5 here


ansa meta image


About this release

We gladly announce the bug-fix version 24.1.5, for ANSA, EPILYSIS, META, KOMVOS and FATIQ.

Contents

Known issues resolved in ANSA
Known issues resolved in META
Known issues resolved in KOMVOS
CAD data translator
Recommended GPU (OpenCL Support) requirements
Virtual Machine Environment


 

go to top

Known issues resolved in ANSA

Modular Run Management

The Build Process of Library Items would fail, when Nastran parameter name length exceeded 10 characters.

Furthermore, referencing Simulation Model Build Performance, "Build Action > Check Assembly Status" function execution has been accelerated by 70%.

Shell Mesh

Upon "Cut" action under "Direct Edit" function, the option to provide tangential point would not work for mesh without underlying geometry.

Decks

ANSA would freeze during output in case Set ranges, containing ids above deck limit, existed.

Laminate Tool

Unexpected termination would occur when multiple layers were selected from GL area and modifications were applied in the layer attribute side panel.

Cross Section

"Beamify > Structure" function execution would apply the section offset incorrectly for Abaqus beams.

Scripting

ANSA would abort abruptly during input of multiple files along with post input script.

 

go to top

Known issues resolved in META

Decks

Concerning nCode, results on elements were not loaded correctly and spotweld results from .fer files were not loaded properly.

Focusing on LS-DYNA, bad handling of type *ELEMENT_TSHELL_BETA led to erroneous properties and possible unexpected termination while saving METADB.

Managing Curve Data

Integral attributes of a curve were not calculated when getting the attributes by script.

Auto Range on plot axis was not functional when navigating through curves, present in groups.

NVH Calculators

Focusing on FRF Assembly, in case FRF_LOAD_DOF string was not present in all subcases of a Nastran .pch file, used for FRF Component definition, incorrect results were generated.

Report

When saving the respective .xlsx file, the font size of the row and column headers was not set to a readable size.

File Export

When saving nodes to CSV format, multiple lines would be written per node.

Session Editor

The Static to Dynamic parameters window would not show the options properly in 4K resolution monitors.

 

go to top

Known issues resolved in KOMVOS

CAD Import/ Export

Upon Input Model Definition, when the input source format in the OS settings was other than the "English (Unites States)" the transformation matrices were not read properly.

Data Management

KOMVOS would create unnecessary copies in the TMP folder upon Export or Edit of compound DM items. Now, both performance and disk space utilization are improved.

Upon Import, attached files/folders with DM Attributes will not appear in the attributes list of the Import wizard.

The function "Promote Version" would report success, even in cases where it failed due to missing versioning ACLs.

 

go to top

CAD data translator

The supported CAD-data formats handled by the CAD DATA Translators are listed below.

- CATIA V5 (R7 - V5-R34) [.CATPart],[.CATProduct]
  Tesselated data [.cgr]

- CATIA V6 (2011x - 2013x) [.3Dxml]
- 3DExperience (2014 - 2022x) [.3Dxml]
- NX (CT based, Unigraphics V11.0 - NX1957, NX CR 2306, NX CR 2312) [.prt]
- NX (UG Open based, NX1953, NX1980, NX2007, NX2206, NX2212, NX2306) [.prt]
- Parasolid (all - 36) [.xmt_txt],[.xmt_bin],[.x_b],[.x_t]
- Pro/ENGINEER (from WF3 to WF5),
  PTC Creo Parametric 2.0 M140, PTC Creo Parametric 3.0 M020,
  PTC Creo Parametric 3.0 M030, PTC Creo Parametric 3.0 M040,
  PTC Creo Parametric 3.0 M090, PTC Creo Parametric 4.0 F000,
  PTC Creo Parametric 5.0 - 10.0
- SolidWorks (2007 - 2023) [.sldprt],[.sldasm]
- JT (v8.0 - v10.8) [.jt]
- Inventor (2010 - 2024) [.ipt],[.iam]
- CoreTechnologie [.ctp],[.cta]
- Rhino(up to v7) [.3dm]
- ACIS(R27) [.sat]

 

go to top

Recommended GPU (OpenCL Support) requirements

The following presents the recommended GPU requirements.:

 GPU :NVIDIA,AMD
 OpenGL Version:3.3
 GPU memory :1GB
 OpenCL Version:1.2


go to top

Virtual Machine Environment

-Any instance of an application launched through a Virtual Machine or Machine of NIC Teamng will not share the same license and will occupy the prescribed number of credits.

 

Regarding the download of ANSA/EPILYSIS/META/CAD data translator v24.1.5 here


BETA CAE Systems Japan Inc.
2-6-3, Shinyokohama, Kohokuku, Yokohama, Kanagawa, 222-0033, Japan
T: 045-478-3840 | Email: betajp.support@cadence.com | http://www.beta-cae.jp/english.html

In case user account and password are unknown,please contact our sales team Email: betajp.sales@cadence.com
If you have any technical questions about BETA CAE Systems softwares,please contact our technical team
Email: betajp.support@cadence.com


Release Announcement BETA CAE Systems suite v24.1.4